Home> Products> Remote IO Modules> Analog Input IO Module> RTD Temperature Acquisition Module 3CH PT100
RTD Temperature Acquisition Module 3CH PT100
RTD Temperature Acquisition Module 3CH PT100
RTD Temperature Acquisition Module 3CH PT100
RTD Temperature Acquisition Module 3CH PT100
RTD Temperature Acquisition Module 3CH PT100

RTD Temperature Acquisition Module 3CH PT100

Get Latest Price
Min. Order:1
Product Attributes

Model No.CT-3713

Packaging & Delivery
Download :

The file is encrypted. Please fill in the following information to continue accessing it

SPS-C Series IO_20260119_11180739
Product Description
CT-3713 RTD Temperature Acquisition Module 3CH PT100
The CT-3713 3-channel RTD temperature acquisition module by Sichuan Odot is engineered for high-accuracy industrial temperature monitoring, directly addressing global pain points such as weak RTD signal susceptibility to noise, difficulty supporting both 2-wire and 3-wire PT100 sensors, ground loop interference, and limited field diagnostics. It provides 3 independent PT100 inputs, compatible with both 2-wire and 3-wire PT100 resistance temperature detectors (RTDs), and features built-in lead-resistance compensation for accurate measurements across a wide range (typically –200°C to +600°C).
A key reliability feature is magnetic isolation between the internal backplane bus and field inputs—eliminating ground loops and suppressing common-mode noise, even in electrically harsh environments near VFDs or motors. Each channel includes a dedicated LED indicator for real-time signal status visibility, enabling faster troubleshooting and reduced downtime. 
With a compact footprint, the CT-3713 fits easily into space-constrained control panels. It has been successfully deployed in European pharmaceutical sterilization systems, North American food pasteurization lines, and Southeast Asian HVAC temperature control units, and integrates seamlessly with Siemens, Rockwell, and other major PLC platforms. 
Compliant with CE and industrial EMC standards, the CT-3713 stands out as a high-isolation, plug-and-play PT100 input module that delivers precise, dependable temperature data for global process automation, energy management, and precision manufacturing applications.
Technical Parameters
Output Parameters
Power Max.37mA @ 5.0Vdc
Isolation I/O to internal bus: magnetic isolation (2.5KVrms)
Field power Not used
Wiring Max: AWG 18
Mounting Type 35 mm Din-Rail
Size 115*14*75mm
Weight 65g
Environment Specification
Operating Temperature of Vertical Installation -35℃~70℃
Operating Temperature of Horizontal Installation -35℃~60℃
Relative Humidity 5~ 95%RH (No Condensation)
Storage Temperature -40℃~85℃
Storage Humidity 5~ 95%RH (No Condensation)
Manufacturing Test Temperature -40℃~75℃
Ingress Protection Rating IP20
Input Parameter
Channel Number 3 channels
LED Indicator 3 Green LED
Resolution 15 bits
Sensor Type PT100
Measurement Range -240~880℃
Measurement Accuracy 0.5℃
Conversion Rate 400ms/3 channels
Diagnostic Function
32766:The sensor is not connected or the cable is disconnected
-32766:short-circuit condition
32765:Chip failure
32767:Temperature overflow 
-32768:Temperature underflow
Application scenarios:
Application 2
FQA
Q:What PT100 sensor wiring configurations does the CT-3713 module support?  
A:The CT-3713 supports both 2-wire and 3-wire PT100 RTD sensors, offering flexible compatibility with various field installation requirements.
Q:What is the measurement resolution and accuracy of this module?  
A:The module features a 15-bit high-resolution ADC, combined with magnetic isolation, to ensure precise and low-noise temperature signal acquisition.
Q:Does the CT-3713 provide input isolation and channel status indication?  
A:Yes, the module uses magnetic isolation between the internal bus and field inputs, and includes a dedicated LED indicator for each analog input channel for real-time status monitoring.
ODOT Solutions
Certifications & Quality Assurance:
ODOT Products comply with international industrial standards, including CE and RoHS, and undergo strict quality control to ensure long-term reliable operation in industrial environments.
certification

certifications
Technical Support
services
Fast Delivery  
ODOT maintains sufficient inventory for standard models.
Most products can be shipped within 1-3 working days, helping customers accelerate project schedules.
Professional technical support and application assistance are available throughout the project lifecycle.
logistics
ODOT In Hannover Messe
expo
Our Team
ODOT Team
Home> Products> Remote IO Modules> Analog Input IO Module> RTD Temperature Acquisition Module 3CH PT100

Copyright © 2026 Sichuan Odot Automation System Co.,Ltd All rights reserved. Privacy Policy

Send Inquiry
*
*

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send