Home> Products> Protocol Converter> Modbus Converter> modbus rtu ascii to profinet adapter
modbus rtu ascii to profinet adapter
modbus rtu ascii to profinet adapter
modbus rtu ascii to profinet adapter
modbus rtu ascii to profinet adapter
modbus rtu ascii to profinet adapter

modbus rtu ascii to profinet adapter

Get Latest Price
Min. Order:1
Product Attributes

Model No.ODOT-PNM02 V2.1

Packaging & Delivery

The file is encrypted. Please fill in the following information to continue accessing it

Product Description
Modbus-RTU ASCll or Non-standard Protocol to Profinet Converter
ODOT-PNM02 V2.1 Modbus (master/slave, RTU/ASCII) to ProfiNET, 2 port serial port (RS485/ RS232 / RS422), supports 50 slots, 200 commands in TIA portal (by configured software), support MAX 60 slaves
1.  Supports protocol conversion between Modbus and PROFINET
2.  Supports 2* RS485/RS232 or 1*RS422
3.  Supports Modbus master or slave, and supports RTU or ASCII
4.  Supports working temperature of -40〜85°C
5.  Supports data area: 2 serial Modbus-RTU/ASCII to PROFIBUS gateway with Max. input 1440 bytesand Max. output 1440 bytes
6.  Supports one key reset
7.  ODOT-PNM02 V2.1 supports 60 slaves (200 read and write commands)
Technical Parameters
Mechanical Property
Shell Aluminum alloy
Weight
335g
Dimension 27.5*110*80mm
Working Temperature -40〜85°C
Storage Temperature -55〜125°C
Relative Humidity 5 〜95% (no condensation)
Input Voltage 19.2〜28.8 VDC
Wiring 3.81mm plug screw terminal
Power Max. 200mA @ 24V
Modbus Serial
Port Number 2
Serial Port RS485/422/232
Wiring 3.81mm plug screw terminal
ESD Protection ±16KV
Rs485 Terminal Resistance External 120Ω
Data Bits 7,8
Stop Bits 1,2
Checkdigit None, even, odd
Baud Rate 2400〜115200bps
Function Code 01/02/03/04/05/06/15/16
Ethernet Interface
Protocol PROFINET
ODOT-PNM02 V2.0 supports Maximum slots 50
ODOT-PNM02 V2.1 supports 60 slaves (200 read and write commands)
Terminal Number 2ways
Speed 10/100Mbps self-adaption, Auto-MDI/MDIX
Connector 8 Pin Rj45
Isolation Protection Electromagnetic isolation
Main Technical Parameters
Installation 35mm standard Din-rail
Supports Protocol PROFINET I/O Device V2.3
PROFINET Data Area Max. input of 1440 bytes & Max. output of 1440 bytes
ODOT-PNM02 V2.0 supports Maximum slots 50
ODOT-PNM02 V2.1 supports 60 slaves (200 read and write commands)
Serial Isolation Optical coupler isolation and power isolation
Serial Number Supports 2*RS485/RS232 orl*RS422
Serial Terminal Resistance need external resistance of 120Q
Serial Protocol Supports Modbus-RTU/ASCII master, Modbus-RTU/ASCII slave
Serial Parameters Supports baud rate of 1200~115200bps, supports none, even and odd digit check
Stations Supports Modbus 62pcs
Function Code Supports to Modbus 01/02/03/04/05/06/15/16
IPGrade IP20
Others
Certificate EMC,CE
Warranty 3 years
Software
Provide XML documents
Provide debug software
FAQ
Q:What Modbus Communication modes and physical interfaces does the ODOT-PNM02 V2.1 support? 
A:The gateway supports both Modbus RTU and ASCII protocols and can be configured as either a Modbus master or slave. It features two serial ports that can be flexibly configured as dual RS485/RS232 or a single RS422 interface, accommodating diverse field device connectivity requirements.
Q:How many Modbus devices can this gateway connect to on the PROFINET side, and what is its data throughput capacity?  
A:It can manage up to 60 Modbus slave devices with support for 200 read/write commands. On the PROFINET side, it offers up to 1440 bytes of input and 1440 bytes of output data area, with up to 50 configurable slots in TIA Portal for efficient data mapping and exchange.
Q:Is this gateway suitable for harsh industrial environments, and does it support quick recovery?  
A:Yes, it operates reliably in extreme conditions with a wide temperature range of -40°C to +85°C. It also features a “one-key reset” function for rapid restoration to factory defaults, significantly simplifying on-site commissioning and maintenance.
ODOT Solutions
Certifications & Quality Assurance:
ODOT Products comply with international industrial standards, including CE and RoHS, and undergo strict quality control to ensure long-term reliable operation in industrial environments.
certification

certifications
Technical Support
services
Fast Delivery  
ODOT maintains sufficient inventory for standard models.
Most products can be shipped within 1-3 working days, helping customers accelerate project schedules.
Professional technical support and application assistance are available throughout the project lifecycle.
logistics
ODOT In Hannover Messe
expo
Our Team
ODOT Team
Home> Products> Protocol Converter> Modbus Converter> modbus rtu ascii to profinet adapter
Contact Us
odotautomation

Mr. odotautomation

Leave a message
Contact Now
Recommend

Copyright © 2026 Sichuan Odot Automation System Co.,Ltd All rights reserved. Privacy Policy

Send Inquiry
*
*

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send